Modbus TCP & RTU Master to BACnet/IP & MS/TP Server Application
Modbus TCP & RTU to BACnet/IP & MS/TP - 3000 points
Modbus TCP & RTU Master to BACnet/IP & MS/TP Server Application
Item number IN7004853K00000
Integrate any Modbus RTU or TCP server device, or both simultaneously, with a BACnet BMS or any BACnet/IP or BACnet MS/TP controller. This integration aims to make Modbus signals and resources accessible from a BACnet-based control system or device as if they were a part of the BACnet system and vice versa.
Features and benefits
-
BACnet/IP client and MS/TP manager support
Both BACnet/IP client and MS/TP manager are supported.
-
Easy integration with Intesis MAPS
The integration process is quickly and easily managed using the Intesis MAPS configuration tool.
-
Commissioning-friendly approach with Intesis MAPS
Templates can be imported and reused as often as needed, significantly reducing commissioning time.
-
Configuration tool and gateway automatic updates
Both the Intesis MAPS configuration tool and the gateway's firmware can receive automatic updates.
-
BACnet Advanced features - calendars, schedules…
BACnet's advanced features, such as calendars, trend logs, schedules, and more, are available.
-
Two Modbus RTU lines for BACnet/IP integration
Two independent Modbus RTU ports are available for BACnet/IP integrations.
-
32 RTU devices per port with no repeater (255 max)
The gateway supports up to 32 Modbus devices per RTU node (without repeater) and up to 255 in total.
-
Template download/generation for Modbus products
Modbus device templates can be generated, imported locally, or downloaded from a repository.
Content of Delivery
Intesis Gateway, Installation Manual, USB Configuration cable.
Not Included (in delivery)
Power supply not included.
Net Width (mm)
106 mm
Net Height (mm)
58 mm
Net Depth (mm)
90 mm
Net Weight (g)
240 g
Mounting
DIN rail mount (bracket included), Wall mount
Input Voltage (V)
For DC: 9 .. 36 VDC, Max: 260 mA, 2.4 W For AC: 24 VAC ±10 %, 50-60 Hz, Max: 100 mA, 2.4 W Recommended voltage: 24 VDC, Max: 100 mA
Power Connector
3-pole
Operating Temperature °C Min
-10 °C
Operating Temperature °C Max
60 °C
Housing Materials
Plastic
Packaging Material
Cardboard
Warranty (years)
3 years
Capacity
Up to 3000 points.
Installation Conditions
This gateway is designed to be mounted inside an enclosure. If the unit is mounted outside an enclosure, precautions should always be taken to prevent electrostatic discharge to the unit. When working inside an enclosure (e.g., making adjustments, setting switches, etc.), typical anti-static precautions should always be followed before touching the unit.
Battery Description
Manganese Dioxide Lithium button battery.
Connectors / Input / Output
Power supply, two EIA-485 ports, Ethernet, Console port USB Mini-B type, USB storage, EIA-232.
Contains Battery
Yes
DIP & Rotary Switches
EIA-485 serial port configuration.
LED Indicators
Gateway and communication status.
Push Buttons
Factory reset.
Recent Posts
-
DUCT CARBON DIOXIDE TRANSMITTER
The duct CO2transmitter uses a highly accurate andreliable non-dispersive infrared (NDIR) sens …2025 Apr 3rd -
Why Veto Pro Pac Has the Best Rated Tool Bags?
When it comes to finding the best rated tool bags, professionals in trades like construction, e …2025 Apr 3rd -
Why Current Sensors Are Important for Building Automation
Sensing some “current events” ahead? And no, we don’t mean tuning into your l …2025 Apr 3rd