Blog
RIB Relay & DC Power Packs
RIB POWER PACKS are designed to provide low voltage power to the ever-increasing sensor systems of today’s building automation systems. With an on-board 20 Amp rated relay, RIB POWER PACKS come ready to switch line voltage to your load when the low voltage control signal is received. Check out some of the features!
On-board 20 Amp rated SPDT relayRequires input power anywhere between 120-277Vac24Vdc, Class 2 rated outputModel RIB21BPP5 (5W) provides up to 210mA @ 24VdcModel RIB21BPP10 (10W) pro
…
2024 Apr 23rd
How to Field Calibrate Humidity Sensors
ACI’s A/RH Duct Series Sensor is a Relative Humidity Transmitter designed for use with electronic controllers in commercial HVAC building management systems. The RH Duct Transmitter can be powered with either AC or DC supply voltage and is field selectable with a 4-20 mA, 0-5 VDC, or 0-10 VDC output signal that is equivalent to 0 to 100% RH.Calibration Although ACI sensors are designed and engineered to drift less than other competitive humidity sensors on the market, over time, factors like env
…
2024 Apr 18th
BAC-9000 Series BACnet VAV Controller-Actuators (B-AAC)
KMC Conquestâ„¢ BAC-9000 series controller-actuators are
designed to operate VAV (Variable Air Volume) terminal units.
The integrated alarming, scheduling, and trending enable these
BACnet Advanced Application Controllers to be powerful edge
devices for the modern smart building ecosystem.
With integrated actuators, internal air pressure sensors, and
other powerful features, they are ideal for new installations
and upgrades of less-efficient equipment. They easily mount
to terminal bo
…
2024 Apr 2nd
HT1D Series Humidity Temp Duct
DESCRIPTIONThe HT1D Series is designed with both the engineer and field technician in mind. The HT1D Series combines excellent stability with reliable operation in 2% or 3% RH accuracy options. Optional temperature transmitters, RTDs and thermistors add further flexibility when ordering. The standard LCD and field replaceable elements make the initial installation and future service a breeze.
2% or 3% RH versions with field replaceable sensorSwitch selectable 5V/10V and 4-20mA RH/T transmitter
…
2024 Mar 27th
Sizing/Selecting A Damper Actuator
The Belimo 10 Step process for sizing and selecting a damper
actuator:1)What is the Area of the damper?We need to find the height and width of the damper. The
customer may provide this in millimetres (mm). If so, multiply the millimeters
by 0.039 to convert it into inches. Once in Inches, multiply the height and
width and divide by 144 to get the area in square ft (sq. ft). If the customer
provides it is Feet (ft), no need to convert it to inches. The height and width
can just be multiplie
…
2024 Mar 25th