Integrate any BACnet MS/TP or BACnet IP server device, with an ASCII BMS or any ASCII IP or ASCII serial controller. The aim of this integration is to make accessible BACnet objects data and resources from an ASCII based control system or device, as if it was a part of the own ASCII system and vice-versa.FEATURESUL CertifiedBTL CertifiedSupport for both ASCII IP and ASCII Serial (232/485)Automatically send a write request to the ASCII bus when its value changesUse personalized ASCII stringsBoth
…
2024 Apr 18th
Joker - Can.Do.Everything.Better. by WERA
When we began to think about open-ended wrenches, we asked ourselves: why does the wrench always have to be flipped over; why does it have an offset design; why does it slip off injuring fingers? The new design of the mouth resulted in a real “Joker” that works even when all other trumps have been played.
1
Limit stop for faster screwdrivingContinual repositioning of the wrench, permanent resetting, power adjustments to avoid any risks of injury? That was yesterday. Today, the Joker prevents a
…
2024 Apr 18th
CPU-1000 Expandable Boiler Control by HBX Controls
CPU-1000 - Central Processing UnitSimple to install and understand but integrated with "Behind the Scenes" sophistication to tackle the toughest HVAC design applications. Intentionally built with both the installer and end-user in mind. The HBX CPU-1000 is a fully integrated control unit based on indoor/outdoor reset technology. This intelligent controller used a PID algorithm, that learns and adapts itself to both the external and internal environment making adjustments to the heating or coolin
…
2024 Apr 18th
Adjusting the Trip Point on the ECM Current Switch: a Quick Step-by-Step Tutorial
Adjusting the trip point of ACI's new ECMCS25-A current switch is a bit different than other current switches. In this guide, we'll walk you through the calibration process step by step, ensuring your ECM motor status indication is spot on.Calibration Steps:
Power Up in Standby Mode: Start by turning on the ECM motor but keeping it in the "standby" position – powered but not turning.Clockwise Adjustment: Rotate the screw clockwise slowly to lower the trip point until the light on the TRIP ADJUS
…
2024 Apr 18th
How to Field Calibrate Humidity Sensors
ACI’s A/RH Duct Series Sensor is a Relative Humidity Transmitter designed for use with electronic controllers in commercial HVAC building management systems. The RH Duct Transmitter can be powered with either AC or DC supply voltage and is field selectable with a 4-20 mA, 0-5 VDC, or 0-10 VDC output signal that is equivalent to 0 to 100% RH.Calibration Although ACI sensors are designed and engineered to drift less than other competitive humidity sensors on the market, over time, factors like env
…